Observer preference for a dedicated medical display vs a standard screen in the detection of dental radioanatomic features
| dc.coverage | DOI: 10.1016/j.oooo.2020.02.011 | |
| dc.creator | Shujaat, Sohaib | |
| dc.creator | Letelier Cáceres, Carolina | |
| dc.creator | De Grauwe, Annelore | |
| dc.creator | de Faria Vasconcelos, Karla | |
| dc.creator | Celikten, Berkan | |
| dc.creator | Jacobs, Reinhilde | |
| dc.date | 2020 | |
| dc.date.accessioned | 2025-11-18T19:55:37Z | |
| dc.date.available | 2025-11-18T19:55:37Z | |
| dc.description | Objective: The aim of this study was to assess observers’ preference for a dentomaxillofacial dedicated medical display (MD) vs a general-purpose standard screen (SS) for in vitro and in vivo observation of normal radioanatomic features. Study Design: The in vitro sample consisted of 2-dimensional (2-D) intraoral (n = 15), panoramic (n = 2), cephalometric (n = 2), and 3-dimensional (3-D) cone beam computed tomography (CBCT) (n = 9) data sets, acquired by utilizing commercially available skull and head-and-neck phantoms. The in vivo sample consisted of 80 radiographs (intraoral = 20; panoramic = 20; cephalometric = 20; and CBCT = 20). In vitro and in vivo data sets were both acquired by using Minray, Promax2-D, and Vistapano Ceph for 2-D images and Accuitomo, NewTom VGi evo, and Promax3-D for CBCT images. Five observers entered screen preferences when evaluating the appearance of radioanatomic structures on MD and SS. Results: Both in vitro and in vivo assessments showed good interobserver and excellent intraobserver agreement. In vitro data suggested a significant preference for MD over SS for viewing radioanatomic features on panoramic and CBCT images, whereas MD was significantly preferred for in vivo images of all imaging modalities (P < .001). Conclusions: Overall, observers preferred MD over SS for both in vitro and in vivo observation of normal radioanatomic features irrespective of the imaging modality. | eng |
| dc.identifier | https://investigadores.uandes.cl/en/publications/1ca1a4dd-4d4a-4b59-8ba3-d60aca280950 | |
| dc.identifier.uri | https://repositorio.uandes.cl/handle/uandes/59358 | |
| dc.language | eng | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.source | vol.130 (2020) nr.2 p.217-224 | |
| dc.title | Observer preference for a dedicated medical display vs a standard screen in the detection of dental radioanatomic features | eng |
| dc.type | Article | eng |
| dc.type | Artículo | spa |